E15: Centrifuges, LYNX II & Parts for LYNX I

HAEMATOSPIN 1300 MICRO HAEMATOCRIT CENTRIFUGE
This is a fast, quiet and easy to operate instrument, robust, well designed with a fail-safe electronic lid-lock. Built and assembled in Europe from durable, high quality components it has fast braking and acceleration and is PCB controlled with a variable timer and LED time display.
A choice of rotors is available separately to allow both haematocrit and micro chemistry preparations or a mixture of the two which give the unit added versatility in use.

  • High Speed Drive developing RCF 13,000g for fast, accurate haematocrits
  • High quality motor for vibration free, quiet operation
  • Excellent acceleration and braking and smooth running characteristics
  • Coated steel body giving total stability and low noise characteristics
  • Simple intuitive operation suitable for any level of operator
  • Range of easy to change and versatile rotors
  • PCB controlled interlock lid
  • Rugged components that will withstand years of hard service
  • Includes 2m power cord, 100 each plain and heparinised 75mm capillary tubes and 1 plate of Cristaseal.

Dimensions: W230 x H245 x D280mm
Weight: 9.75kg.

User Notes

Haematocrit (US hematocrit) definition:
a) An instrument which separates blood into cells and plasma, usually by centrifugation.
and also
b) The ratio of compacted red cells as a proportion of blood, as read in a capillary tube after centrifugation.
Decreased haematocrit (red cell) levels are associated with anaemia, hyperthyroidism, cirrhosis, bone marrow failure and numerous other pathogenic conditions.

Haematocrit accessories
Micro-haematocrit tube reader - see E1502 on this page
Rotor reader and magnifier (placed directly onto rotor) - see E1562 on this page
Cristaseal (wax sealant for capillary tubes) - on page H6
Capillary tubes, plain and heparinised (Best buy!) - on page H6

Rotors and tubes
E1881 Fixed angle acetal rotor, 20 x 1.5 - 2.0mL micro tubes, see LCA09 on page L9
A durable black acetal machined rotor to take 20 micro chemistry tubes up to 2mL volume, with numbered tube positions for routine sample identification. The rotor inclines the samples at 45 degrees and runs at 11800 rpm giving RCF 14000g.

E1890 Fixed angle acetal rotor, 8 x 1.5 - 2.0mL micro tubes (LCA09)
A durable black acetal machined rotor to take 8 micro chemistry tubes up to 2mL volume, with numbered tube positions for routine sample identification. The rotor inclines the samples at 30 degrees and runs at 16000 rpm giving RCF 19000g.

E1971 Haematocrit rotor, 24 x 75mm capillary tubes
A balanced machined and perfectly concentric disc of solid aluminium, anodised and silk screened to give high integrity and long life. The rotor has numbered tube positions for routine sample identification.

E1985 Multi combination rotor, 8 x capillary tubes, 12 x 1.5 - 2mL micro tubes (LCA09), and/or 4 x 10.25mm diam. 2mL/3mL Vacutainers, and/or 4 x 12mm diam screw cap tubes
A further variation on the rotors above, this is the ideal rotor for users with a wider variety of sample types to process. The rotor takes 16 standard 75mm capillaries, and several different sizes of micro tubes, to accommodate screw cap lids, and both 11 and 12mm diameter micro tubes.

E1986 Combination rotor, 16 x capillary tubes, 16 x 1.5 - 2mL micro tubes (LCA09)
A mixed capacity rotor to allow both haematocrit capillaries and capped micro tubes to be run in the same load and to give the operator a choice of options to reduce the need for rotor changes. The design is a modified version of the standard Haematocrit rotor above.

Rotors not included - please specify which one you require.

Also available: Lid seals/cushions

E1300 Haematospin 1300 haematocrit centrifuge 230V AUD1,812.00 stock? Add to shopping cart
E1881 Acetal rotor for micro tubes, 20 place AUD289.00 stock? Add to shopping cart
E1890 Acetal rotor for micro tubes, 8 place AUD195.00 stock? Add to shopping cart
E1971 Haematocrit rotor w/lid, 24 place AUD293.00 stock? Add to shopping cart
E1985 Multi combination rotor w/lid, 24 place AUD324.00 stock? Add to shopping cart
E1986 Combination rotor w/lid, 32 place AUD324.00 stock? Add to shopping cart
E1999 Replacement brushes for Haematospin motors AUD44.00 /set stock? Add to shopping cart
E2504 Rim gasket for rotor E1971 AUD8.00 stock? Add to shopping cart
E2989 Rim gasket for rotors E1985, E1986 AUD7.00 stock? Add to shopping cart
E1300
E1300

E1971, E1300 -



Top

HAEMATOSPIN 1400 MICRO HAEMATOCRIT CENTRIFUGE
The Haematospin 1400 is a highly dependable and easy to operate machine designed to give decades of solid service. Built from durable, high quality components it is the ideal tool in haematology laboratories and clinics, producing reliable and accurate haematocrits year in year out. Its successful classic design is in widespread use world wide.

A choice of rotors is available separately, to allow micro chemistry preparations and give the unit versatility in use.

  • High Speed Drive developing RCF 13,000g for fast, accurate haematocrits
  • E1400DS has a second low speed option developing RCF 3300g
  • High quality motor for vibration free, quiet operation
  • Excellent acceleration and braking and smooth running characteristics
  • Lightweight coated die cast aluminium body
  • Simple intuitive operation suitable for any level of operator
  • Range of easy to change and versatile rotors
  • Rugged components that will withstand years of hard service
  • Includes 2m power cord, 100 each plain and heparinised 75mm capillary tubes and 1 plate of Cristaseal.

Dimensions: H230 x 270mm diam.
Weight: 5.1kg.

Rotors and other parts listed under the Haematospin 1300 also suit the 1400.

Rotors not included - please specify which one you require.

User Notes

E1400 Haematospin 1400 haematocrit centrifuge 230V AUD1,479.00 stock? Add to shopping cart
E1400DS Haematospin 1400 DS haematocrit centrifuge 230V, dual speed AUD1,848.00 stock? Add to shopping cart
E1400
[click to enlarge]
E1400



Top

HAEMATOCRIT ROTOR READER
For micro-haematocrit measurement.
A simple and well-made gauge designed to give fast, easy and accurate haematocrit measurements straight off the rotor.

E1562 Haematocrit rotor reader AUD114.00 stock? Add to shopping cart
E1561 Magnifier for rotor reader AUD46.00 stock? Add to shopping cart
E1562 - E1561, E1562
E1561, E1562



Top

HAEMATOCRIT TUBE READER
For micro-haematocrit measurement.
A superbly made instrument for fast, easy and accurate haematocrit measurements. Precision printed, intuitive reader scale.

Using the Reader
  • Position tube in slot within acrylic slider. The base line of Reader must intersects base of red cells
  • Move tube holder slide, so that the top line intersects top of plasma.
  • Adjust knob (on left, it moves line under the slider) so that the middle line intersects top of red cells.
  • Read percentage P.C.V on scale at right.

The process is simple, fast and accurate.

E1502 Haematocrit tube reader AUD150.00 stock? Add to shopping cart
E1502
E1502



Top

MINI CENTRIFUGE, 6 POSITIONS
The Benchmark mini centrifuge is ideal for quick spin down of micro samples.

Features
  • Clear lid for safe observation of samples
  • Electronic safety cut-off
  • Quick acceleration to maximum speed (6,000rpm/2,200rcf)
  • Stops in seconds
  • Sophisticated motor mounting system provides quiet, vibration-free operation
  • 2 Rotors and tube adapters included
  • The rotors can easily be interchanged by the user in a matter of seconds

The centrifuge comes with a round rotor for six standard microtubes (1.5mL to 2.0mL) as well as a strip tube rotor for 2 x 8-PCR strips or sixteen individual 0.2ml tubes. Also included is a set of 6 adapters for 0.4 - 0.5mL tubes.
Both rotors and the adapters are also available separately.

Specifications
RPM 6,600rpm
RCF 2,200xg
Maximum capacity of rotors
   Microtube rotor 6 x 1.5/2.0mL
   PCR strip rotor 2 x 8-PCR strips or 16 x 0.2mL tubes
Dimensions (WxDxH) 126 x 138 x 100mm
Operating temperature range +4ºC to 65ºC
Warranty 1 year
Electrical 230V AC, 50 Hz

EB1006 Mini centrifuge with 2 rotors, 6 positions AUD268.00 stock? Add to shopping cart
EB1006-RR Rotor for 6 x 1.5 - 2.0mL tubes AUD48.00 stock? Add to shopping cart
EB1006-RS Rotor for 2 x 8-PCR strips or 16 x 0.2mL tubes AUD48.00 stock? Add to shopping cart
EB1006-TA Adapters for 0.5mL tubes AUD35.00 /pk/6 stock? Add to shopping cart
EB1006 - Mini centrifuge with round rotor for 6 microtubes
Mini centrifuge with round rotor for 6 microtubes

EB1006-TA, EB1006 - Strip-tube rotor and adapters for 0.5mL tubes
Strip-tube rotor and adapters for 0.5mL tubes



Top

MINI CENTRIFUGE, 8 POSITIONS
The MyFuge™ mini centrifuge is a compact, personal centrifuge, ideal for quick spin downs of microtubes and PCR tubes. It is very easy to use. Simply close the lid and the rotor instantly reaches 6,000 rpm. Open the lid, and the rotor quickly decelerates to a stop for removing samples.
An increased capacity, eight-position 1.5/2.0mL microtube rotor is included and comes installed. A second rotor for 0.2mL PCR tubes and strips is also included and stored with the rotor removal key in a convenient compartment on the underside of the centrifuge.
Adapters for 0.5mL and 0.2mL tubes are included.

Specifications
Speed 6000rpm / 2000xg
Capacity 8 x 1.5/2.0mL tubes
16 x 0.2mL PCR tubes
2 x 0.2mL PCR strips
Dimensions 114 x 150 x 114mm
Weight 1kg
Electrical 100 to 240V 50-60 Hz

EBC1008 MyFuge™ mini centrifuge with 2 rotors, 8 positions AUD340.00 stock? Add to shopping cart
EBC1008
[click to enlarge]
EBC1008

EBC1008A, EBC1008 - Rotor storage compartment
Rotor storage compartment



Top

LYNX II AUTOMATED TISSUE PROCESSOR

Lynx II Automated Tissue Processor for Histology and Microscopy is a state-of-the-art tissue processor which is compatible with all plastic resins and paraffin waxes.

Introduction
Lynx II is designed to be the successor of the Lynx Tissue Processor with several enhancements including the optional processing of larger size samples for Histology.

The Lynx II holds 24 reagent vials for EM processing. Optional HP (Histology processing) may be done with 12 larger size reagent vials for HP processing. In both EM and HP modes, Lynx II has two, independently controlled, heating/cooling stations.

Operational Overview of Lynx II
Lynx II is a batch mode, tissue processing system. The tissues may be processed for EM or HP. Tissues of either type are processed in the same manner: Samples are mounted on the sample arm and reagents are loaded on the reagent carousel. Based on the selected program by the user, the Lynx II rotates the reagent carousel until the selected reagent station is at the processing station. At the processing station the sample is lowered in the reagent. Based on the selection of agitation and vacuum, the Lynx II periodically moves the sample arm to provide agitation and applies vacuum when the agitation is not in progress. Once the programmed time in a given reagent is over, the sample is raised and the next reagent is rotated in the processing station.

The operator may select the processing for EM or HP by the program numbers. Programs 1 through 10 are used for EM processing and programs 11-20 are used for HP processing. In addition to the proper program number selection, it is the responsibility of the end user to use the proper carousel positions and the appropriate type of reagent vials based on the selection of EM vs. HP processing. Once the unit is properly configured for EM or HP processing, the operator loads the reagent carousel and the samples, selects the desired program and starts the run.

At the end of the run, the sample is retained in the last reagent until the operator removes the sample.

Features
  • 12 reagent vials for HP processing, each 125mL volume
  • 24 reagent vials for EM processing, each 25mL volume
  • 10 Programs for EM and 10 programs for Histology
  • Two independently controlled heating/cooling stations
  • Easy replacement of reagent carousel
  • Paraffin processing
  • Sample agitation
  • Vacuum infiltration during processing
  • Choice of plastic and metal containers for improved chemical compatibility and heat transfer
  • Optional external media based interface to a PC for ease of programming and allowing for the editing of programs on a PC and the transfer of programs between the Lynx II and the PC
  • Built-in fume extraction and ability to connect the discharge hose to lab exhaust system
  • Internal battery back-up during power fail to protect the samples
  • Ability to continue run after power interruption
  • User Friendly Operator Interface
  • Optional external UPS for continued processing during longer power outages

Functional Specifications
System Configuration
1. Lynx II is designed with the following functional modules.
  • Rotary mechanism to rotate the reagents
  • EM and HP reagent carousel
  • Up/Down mechanism to move the sample in and out of the reagent as well as to provide the agitation
  • EM and HP Sample arms
  • Tight seal for all reagent containers except for the one at the processing station.
  • Vacuum pump and a pressure sensor or a switch
  • Two Peltier operated heating/cooling station with independent temperature sensors and controls
  • Fume extraction fan and air flow sensor

2. Reagent Carousel
A reagent carousel may be installed, either a 24-position carousel for holding EM reagents or a 12-position carousel for holding HP reagents. The EM carousel holds cylindrical vials that are approx. 1.2" in diameter and 2.5" tall whereas HP vials are approx. 2.2" diameter (to hold 1.75" x 1.2" cassette flat) and 2.5" tall. The carousel is approx. 12" in diameter. Each vial has a flange for ease of handling. The vials are available in either plastic or aluminum. The vials may be mixed and matched between the metal and the plastic vials on a given carousel for certain kinds of processing.

The Lynx II has a built in sensor to detect that the proper reagent vial types (EM vs. HP) are installed on the unit before starting a run. Ability to detect only one of the two vial types is sufficient.

3. Sample Arm
The sample arm holds either an EM sample holder assembly or an HP sample holder assembly. Each sample holder assembly is designed to mount on the arm at a location to center the samples in its respective reagent container. The Sample Arm top may be changed to accommodate different samples.

4. Agitation and Vacuum
The arm provides a gentle agitation (approx. 5 mm up and down travel at a rate of 2.5 mm per second or one up/down agitation per second) once the sample is in the reagent container. Five agitation strokes are executed in 5 seconds and repeated every 45 seconds. If vacuum infiltration is selected, the agitation will be applied for 5 seconds followed by 40 seconds of vacuum. These agitation-only or the agitation-vacuum cycles will be repeated for the duration of the station time.

The sample holder assembly has a fitting to attach the vacuum hose from the vacuum pump.
5. Heating-Cooling Stations
The Lynx II provides 2 independent, identical heating-cooling stations (HCS). Each HCS is heated or cooled by a Peltier module and has its own temperature sensor. One HCS is located at the sample processing station and the second one is located one position prior to the sample processing station. This arrangement allows for the pre-heating or pre-cooling of the reagent for a program where the reagents are arranged in a sequential, contiguous manner.

Each HCS can be programmed to be between 4 deg. C and 65 deg. C. The accuracy of the actual temperature will be +/- 2 deg. C measured on the surface of the Heating – Cooling station. The set point at the HCS surface is reached within 7 minutes of the arrival of the reagent at the station.

6. Fume Control
Lynx II provides a fume extraction fan to direct fumes from the reagent/ sample area to an exhaust port. An external hose may be connected to the unit and the hose may be directed to a fume hood or to laboratory exhaust system. The fume extraction is designed to ensure that the fumes are diverted away from electronics and the mechanism components.

7. Lid/Cover
An acrylic cover with a latch is part of the fume control system. Controller of the system can detect if the cover is latched or not. By default, a run cannot be started (and will pause) if the cover is not in place. However,there is a software override will allow for the running of the unitt without closing the cover.

8. Seal for the Reagent Vials
A tight seal is provided to cover all reagent vials except for the one under the processing station.

Reagents Used
Materials for various components and subsystems of Lynx II are compatible with the following reagents during the processing.

HP Processing
  • Formalin
  • Alcohol
  • Xylene
  • Xylene Substitutes
  • Water
  • Paraffin
  • 10% bleach solution (to wipe clean the system)

EM Processing
  • Buffers
  • Osmium Tetroxide
  • Ethyl Alcohol
  • Acetone
  • Propylene Oxide
  • Epoxy/acrylic resins

9. Operation During Power Outage
The Lynx II contains a small internal battery (that is capable of moving the sample from up position to down position and to move the carousel in the next reagent position at least three times without being re-charged) to preserve the sample during a power outage. When the electronics in Lynx II detects that the A/C power is about to fail, the Lynx II will shut down the power to the Peltier elements at both heating/cooling stations. Next, it will ensure that the samples are down in a reagent container. If the samples are out of a reagent vial (since Lynx II was just about to rotate the carousel to the next reagent position or was in the middle of the rotation), the carousel will be rotated by one position and then the samples will be lowered in to the reagent at the processing station. The time when the power fail warning was activated will be recorded and the unit will go in the stand by mode.

Once the power is restored and is maintained for at least 30 seconds, Lynx II will resume the run. As Lynx II resumes run, the station time count down does not resume until the heating/cooling stations have reached the desired temperatures. The station time countdown does not begin for additional 60 minutes if the temperature at the processing station or at the previous station was above 55 deg. C during an HP run. This feature ensures that the paraffin at either of the two stations completely melts before moving to the next station

Specifications:
Dimensions:
Max Width: 22.5"
Max Depth: 19.0"
Max Height: 12.0" (cover closed)
Max Weight 50lb (32 kg)
Electrical Design:
Display: 8 lines x 20 column text only LCD
Keypad: Membrane style keypad with tactile feed back
Mechanism Drive: Stepper Motors
Power Requirements: 100 - 115 volts AC, 50-60 Hz, 8 Amps Max
230 volts AC, 50-60 Hz, 4 Amps Max
Back-up power: NiCd Battery, 12 volts, 1 Amp-hour
Fuse Rating:
100 – 115 volt version 8 Amps x 250 Volts AC, Time Delayed (Slo-Blo)
230 volt version 5 Amps x 250 Volts AC, Time Delayed (Slo-Blo)
Operating Environmental Conditions:
Ambient Temperature: 20 to 32 o C (70 to 90° F)
Relative Humidity: 20-80% non-condensing
Ambient Pressure: 28"-32" (70-80 mm) of Hg
Storage/Transportation Conditions:
Temperature: 10-40 deg C (50 to 102° F)
Humidity: 15%-80% non-condensing
Pressure: 28"-32" (70-80 mm) of Hg


Lynx II accessories and spare parts
L12610 Histology Kit
(Histo Sample Holder, Histo Sample Arm, Histo Carousel, Power Cord, Operator Manual, Histo Aluminum Containers (24), Histo Plastic Containers (36), Plastic Caps (36), Exhaust Hose, Small Cassettes (100), 2 Sample Record Note Pads, Spare Fuses.

L12612 Electron Microscopy Kit
(EM Sample Holder, EM Sample Arm, EM Carousel, Loading Jig, Power Cord, Operator Manual, Aluminum Containers (24), Plastic Containers (72), Plastic Caps (72), Exhaust Hose, Small Baskets (100), Large Baskets (100), Basket Lids (100), 2 Sample Record Note Pads, Spare Fuses.

L12655 EM Reagent Vials, Bag of 72
L12656 EM Regent Vial Cap, Bag of 72
L12657 HP Reagent Vials, Bag of 36
L12658 HP Reagent Vial Cap, Bag of 36
L12659 EM Aluminum Container (Box of 24)
L12660 HP Aluminum Container (Box of 12)
L13154 EM Sample Holder Assembly (Basket Stem Assembly)
L12663 HP Cassette Holder Assembly
L12661 Vacuum Pump Tubing (1 each)
L12662 Vial Seal Assembly
L12995 EM Sample Arm Seal
L12996 HP Sample Arm Seal
L12952 EM Carousel (Without Aluminum Containers)
L12953 HP Carousel (Without Aluminum Containers)
L12664 Replacement Back-up Battery
L12665 Lynx II Operator Manual
L12667 Lynx II Service Manual

The Lynx II for Microscopy comes with: EM Sample Holder, EM Sample Arm, EM Carousel, Loading Jig, Power Cord, Operator Manual, Aluminum Containers (24), Plastic Containers(72), Plastic Caps (72), Exhaust Hose, Small Baskets (100), Large Baskets (100), Basket Lids (100), 2 Sample Record Note Pads, Spare Fuses.

The Lynx II for Histology comes with: Histo Sample Holder, Histo Sample Arm, Histo Carousel, Power Cord, Operator Manual, Histo Aluminum Containers (24), Histo Plastic Containers(36), Plastic Caps (36), Exhaust Hose, Small Cassettes (100), 2 Sample Record Note Pads, Spare Fuses.

The Lynx II for Microscopy and Histology comes with everything found in both units.

All of the above accessories may be purchased separate or in the kit.

Consumables for Lynx I and II are on page H3

EL12600 Lynx II automated tissue processor for microscopy ask stock?
EL12601 Lynx II automated tissue processor for histology ask stock?
EL12602 Lynx II automated tissue processor for microscopy & histology ask stock?
EL12600A, EL12600 - Lynx II Automated Tissue Processor for Histology and Microscopy
Lynx II Automated Tissue Processor for Histology and Microscopy

EL12600B - EL12600

EL12600C - EL12600

EL12600D - EL12600

EL12600E - EL12600



Top

USER REPLACEABLE PARTS FOR LYNX I

E300-0008 Location pin for LYNX processor AUD57.00 stock? Add to shopping cart
E300-0015 Cap (TurnTable Lockings) for LYNX processor AUD127.00 stock? Add to shopping cart
E300-0019 Lid for LYNX processor AUD1,127.00 stock? Add to shopping cart
E300-0139 User manual for LYNX processor AUD62.00 stock? Add to shopping cart
E300-8041 Exhaust Hose for LYNX processor AUD106.00 /3m stock? Add to shopping cart
E300-8105 Printer data cable for LYNX processor AUD365.00 stock? Add to shopping cart
E300-9010 Basket stem and foot assembly for LYNX processor AUD133.00 stock? Add to shopping cart
E300-9011 Loading jig for LYNX processor AUD249.00 stock? Add to shopping cart
E300-9014 Heater/Cooler for LYNX processor ask stock?
E300-9016 Vial seal assembly for LYNX processor AUD785.00 stock? Add to shopping cart
E300-9017 Vial lid assembly for LYNX processor AUD99.00 stock? Add to shopping cart
E300-9022 Turntable for LYNX processor AUD468.00 stock? Add to shopping cart
E300-9023 Vial retaining band for LYNX processor AUD89.00 stock? Add to shopping cart
E300-9034 Front panel assembly for LYNX processor AUD1,777.00 stock? Add to shopping cart
E300-9100 Starter kit for LYNX processor AUD1,022.00 stock? Add to shopping cart
E300-9500 Assembly Heater/Cooler for LYNX tissue processor ask stock?
E306-0830-0001 Key for LYNX processor AUD18.00 stock? Add to shopping cart
E3009016 - E300-0008



Top

Home Email
E15
E15